Snow Guards and Metal Roofs

Dave Kowch
September 26, 2024

Reposted with permission  – original post https://blog.s-5.com/blog/will-snow-guards-damage-my-metal-roof

Won’t I Damage My Roof if I Attach Snow Guards to it?

Even the best snow guard system can cause damage if it is not properly engineered to the project. That is why any system must be prudently tested, engineered and time-proven. A properly engineered snow guard system takes into account:

  • Specific roof slope of the project
  • Roof size
  • Design snow load, and
  • Allowable holding capacity on the specific roof type being used.

How Do I Know How Much Snow My Roof Can Handle?

“Design snow load” is the downward force for which a building's roof is designed (the weight of accumulated snow and ice it can handle). Access this information from your building contractor, project engineer or in the structural plans for the building. “Allowable capacity” is the tested failure load divided by a factor of safety to ensure the product cannot fail in service.

Don’t expose yourself to liability or leave your customers unprotected. Install snow guards!

Seeking a technical guide for engineering-based snow guard design?

______________________________________________________________________________

 Download Qualifying Snow Retention Systems by the Metal Construction Association (MCA).

Download MCA's Technical Bulletin on Snow Guards CTA Button - S-5!

The three main types of snow guards:

  • Structure Attachment (Brackets) – Attaches by penetrative, mechanical fastening through the roof and into the building’s structural components (typically purlins or trusses).
  • Clamp-Mounted (Clamps) – Uses a metal roof seam to fasten a clamp onto - with round-point setscrews that apply pressure onto the seam but do not puncture the metal.
  • Adhesive/Stick-On (Glued-On/”Peel and Stick”) – Attaches (chemically) proprietary variations of cleats to the roof surface.

The above are either unitized (dis-continuous) or continuous. Unitized snow guards (snow cleats, pad-style snow guards) can be single- or multi-component and do not require a continuous cross-member (a bar or pipe that forms a connection to all the pieces). Normally used in a redundant manner, unitized snow guards rely on snowpack “bridging” between adjacent devices. They often attach via adhesives.

Continuous snow guards (rail-type, snow fence, snow rail, pipe-style snow guards) use brackets or clamps and cross-members anchored to them to prevent sliding snow. Continuous snow guards can be made up of one or multiple cross-members.

The Pros and Cons

Structure Attachment

Pros

  • Mechanical attachment is reliable over time
  • Strong, secure as tested (if properly designed, engineered, installed, waterproofed)
  • Generally compatible with roofs that are attached with screws that penetrate the roof’s surface, attaching it to the structure
  • Can be mounted after roof has been installed
Example of a waterproofing failure in a mechanically-attached (non-penetrating) snow guard system

Example of a waterproofing failure in a mechanically-attached (non-penetrating) snow guard system

Snow guards that appear “invisible” are  highly reflective when actually installed on a roof

Snow guards that appear “invisible” are highly reflective when actually installed on a roof.

Cons

  • Must drill holes into the roof for attachment
  • Must know and use prudent waterproofing that lasts the life of the roof
  • Must understand part design and be able to evaluate the testing conducted and how it relates to that part
  • Difficult to waterproof as penetration must not jeopardize thermal movement of roof
  • Most of these types of systems are not appropriately tested for holding capacity

Clamp-Mounted

Pros

  • Does not require drilling holes in roof that could leak – no waterproofing required
  • Will not fatigue due to thermal heating or cooling of roof
  • Can be mounted after roof has been installed
  • Uses setscrews that won’t damage the metal
  • Non-penetrating clamps won’t void roof manufacturer’s warranty

Cons

  • Sliding force of snow is transferred to clamp and to roof panels – must know holding strength of the system. Few systems on the market have been adequately tested for this.
  • Damage to roof if testing/engineering protocols not observed
  • Can only be used on standing seam type roof profiles

Adhesive (Glued-On)

Pros

  • Appears lower cost at first glance (but… see below)
  • Snow guards attach directly to surface of most metal roof profiles without penetration
  • “Clear” plastic, appears “invisible” (but… see below)
Roof damage on metal roof caused by avalanching snow. No snow guards in use

Roof damage caused by avalanching snow - no snow guards in use

Damage from stick-on snow guards because adhesive degrades and rips away paint from panel

The holding strength of stick-on snow guards diminishes with age and as the adhesive degrades. Once the bond fails, the guard can rip away paint from the roof panel.

Cons

  • Products that appear to be “invisible” on your desk are highly reflective when actually installed on a roof.
  • Adhesives diminish in holding strength (e.g. with time, exposure, heat, cold, light, moisture, ozone), making proper engineering impossible.
  • Careful surface preparation is required (Learn more about this process here).
  • Upon failure, can rip away paint and protective roof coatings, voiding material warranties and leading to corrosion of metal.
  • Glue has low lifespan due to U.V. exposure, other environmental factors so replacement is required every few years (real costs mount up over time).
  • Adhesives are not recommended for use by many industry organizations and user groups due to the above points.

So, Will Snow Guards Damage Your Roof?

They sure can!

But only if you don’t take the above precautions into consideration.

If not properly engineered, the weight of the snow can be too much for a single piece when glued onto the roof – or even when mechanically-attached.

Failed plastic snow guards on a metal roof. Premature fading and premature adhesive failure due to UV exposure.

Failed plastic snow guards on a metal roof - premature fading and premature adhesive failure due to UV exposure

In all instances, mechanically-attached snow guard systems are the best method for a variety of roof types and snow loads because their holding strength is not diminished with time. But only when properly tested, engineered and installed, will these products work as intended without causing harm to the roof. This is the most proven and effective way to prevent rooftop avalanches.

What Can You Do to Avoid Damage to Your Metal Roof?

  • Verify that your specific roof profile has been tested with the specific system you want to install.
  • Ask for written proof of this testing on the actual profile and substrate by an accredited lab.
  • You should also ask to see the engineered calculations.
  • Don’t be tempted to just accept any sales hype thrown at you to cover up for a lack of facts or real testing.
  • Ask for the proof!

Need help deciding on the right snow guard system for your metal roof? Learn more about the only snow guard system good enough to be warranted for the life of the roof. All of our systems are rigorously tested and time-proven. Test results are displayed at our website and engineering tools are also available there to design any system for any metal roof.

Subscribe to our newsletter

Keep up with the latest in metal roof attachment solutions, designs, and industry news.

By clicking Sign Up you're confirming that you agree with our Terms and Conditions.
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Courriel : sales@skyproducts.ca

1,855,888,6869

Commençons

Si vous êtes trop occupé pour discuter maintenant, veuillez entrer votre numéro de téléphone cellulaire et votre message ci-dessous et nous vous enverrons un SMS dès que possible.

Je vous remercie ! Votre soumission a bien été reçue !
Oups ! Quelque chose s'est mal passé lors de la soumission du formulaire.